Installation and Operating Manual
1010 319867-000
KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE
WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED.
POWER VENT GAS MODELS
ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS
PURCHASED.
HYBRID GAS WATER HEATERS
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
ANSI Z21.10.3b-2008
www.statewaterheaters.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 59 60

Shrnutí obsahu

Strany 1 - HYBRID GAS WATER HEATERS

Installation and Operating Manual1010 319867-000KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCEWHENEVER MAINTENANCE ADJUSTMENT OR SERVI

Strany 2 - TABLE OF CONTENTS

10 www.statewaterheaters.com For all side wall terminated, horizontally vented power vent, gas fueled water heaters installed in every dwelling, build

Strany 3 - www.statewaterheaters.com 3

www.statewaterheaters.com 11FIGURE 3 WATER PIPING - MIXING VALVE USAGEThis appliance has been design certifi ed as complying with ANSI Z21.10.3/CSA 4

Strany 4 - GENERAL SAFETY

12 www.statewaterheaters.com and the physically or developmentally disabled. If anyone using hot water from this heater fi ts into one of these groups

Strany 5

www.statewaterheaters.com 13Also, the water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle. HAN

Strany 6 - INTRODUCTION

14 www.statewaterheaters.com When installing the heater, consideration must be given to proper location. Location selected should be as close to the w

Strany 7 - www.statewaterheaters.com 7

www.statewaterheaters.com 15Screws ScrewsTopCasing (Front)FIGURE 7ScrewsFIGURE 8FIGURE 9After the heater has been positioned and the earthquake stra

Strany 8 - 8 www.statewaterheaters.com

16 www.statewaterheaters.com COMBUSTION AIR AND VENTILATIONA gas water heater cannot operate properly without the correct amount of air for combustio

Strany 9 - INSTALLATION CONSIDERATIONS

www.statewaterheaters.com 17FIGURE 11B. ALL AIR FROM OUTDOORS: (See Figures 12, 13 and 14)The confi ned space should be provided with two permanent

Strany 10 - 10 www.statewaterheaters.com

18 www.statewaterheaters.com 6. Louvers and Grilles: In calculating free area, consideration should be given to the blocking effect of louvers, grille

Strany 11

www.statewaterheaters.com 19limited warranty. Thermal expansion can also cause intermittent temperature-pressure relief valve operation: water disch

Strany 12 - 12 www.statewaterheaters.com

2 www.statewaterheaters.com TABLE OF CONTENTSSAFE INSTALLATION, USE AND SERVICE 3GENERAL SAFETY 4INTRODUCTION 6 Get To Know Your Water Heater - Gas

Strany 13 - Flammable Vapors

20 www.statewaterheaters.com The temperature-pressure relief valve must be installed directly into the fi tting of the water heater designed for the re

Strany 14 - 14 www.statewaterheaters.com

www.statewaterheaters.com 21 GAS PIPINGMake sure gas supplied is same type listed on model rating plate. The inlet gas pressure must not exceed 14

Strany 15

22 www.statewaterheaters.com a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with

Strany 16

www.statewaterheaters.com 23 VENT PIPE TERMINATIONSTREET ELBOW NORMAL ELBOWPREFERRED PRACTICE:90° LONG SWEEP ELBOW (LESS RESTRICTIVE)BACK TO BACK EL

Strany 17

24 www.statewaterheaters.com Vent piping must slope up from heater to termination a minimum of 1/8 in. (0.3cm) rise per 4 ft. (1.2m) of vent pipingTER

Strany 18 - 18 www.statewaterheaters.com

www.statewaterheaters.com 25 CONDENSATEThis water heater is a condensing unit and requires a drain to be located in close proximity to allow the con

Strany 19 - Rear View

26 www.statewaterheaters.com SEQUENCE OF INSTALLATIONSCut a length of PVC pipe about 3.5 in. (9cm) longer than the wall thickness at the opening. Glu

Strany 20 - 20 www.statewaterheaters.com

www.statewaterheaters.com 27VENT PIPING TO BE SLOPED (DOWN) TOWARD HEATER TO PREVENT WATER FROM COLLECTING.6 in. (15 cm) MIN. LENGTHATTACH 45° TERMI

Strany 21

28 www.statewaterheaters.com FIGURE 28A VENT USED IN A SPECIAL VENTING SYSTEM WITH POSITIVE VENT PRESSURE AND PASSING THROUGH A ROOF SHALL EXTEND AT L

Strany 22

www.statewaterheaters.com 29PRIMERIt is recommended that Tetrahydrofuran (THF) be used to prepare the surfaces of pipe and fi ttings for solvent weld

Strany 23

www.statewaterheaters.com 3Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.M

Strany 24

30 www.statewaterheaters.com D. Inspection, cleaning, priming Visually inspect the inside of the pipe and fi tting sockets and remove all dirt, gr

Strany 25

www.statewaterheaters.com 31 U.S. POWER VENT WARNINGVENT HOOD(S) MAY BEEXTREMELY HOTDURING OPERATION.FIGURE 31 CAUTIONTO PREVENT EXHAUSTING PRODUCTS

Strany 26 - 26 www.statewaterheaters.com

32 www.statewaterheaters.com ELECTRICAL CONNECTIONSThe water heater must be connected to a properly grounded electrical branch circuit. A dedicated

Strany 27

www.statewaterheaters.com 33OPERATING INSTRUCTIONS Changing the Standby StatusWhen the Standby Button is pressed, the Status changes to normal opera

Strany 28

34 www.statewaterheaters.com Numeric DisplayNumeric information such as temperature set-point, maintenance codes and error codes are displayed using

Strany 29

www.statewaterheaters.com 35 WIRING DIAGRAMObey local codes and electric utility requirements when you install or service the water heater.This app

Strany 30

36 www.statewaterheaters.com LIGHTING INSTRUCTIONS1. Set the thermostat to the lowest setting.2. Set the ON/OFF switch on the control panel to the “

Strany 31 - FIGURE 31

www.statewaterheaters.com 37 HEAT CYCLE DEFINITIONSSTATE DESCRIPTIONPre-purge If the heat engine initial call-for-heat is successful (all checks are

Strany 32

38 www.statewaterheaters.com TEMPERATURE REGULATIONFIGURE 35It is recommended that lower water temperatures be used to avoid the risk of scalding. I

Strany 33 - OPERATING INSTRUCTIONS

www.statewaterheaters.com 39Water TemperatureTime for 1st Degree Burn (Less Severe Burns)Time for Permanent Burns 2nd & 3rd Degree (Most Severe

Strany 34 - 34 www.statewaterheaters.com

4 www.statewaterheaters.com GENERAL SAFETY

Strany 35 - FIGURE 34

40 www.statewaterheaters.com Water Circulation PumpA circulation pump is integrated into the heat engine for the Hybrid application. The pump serves

Strany 36 - TO TURN OFF GAS TO APPLIANCE

www.statewaterheaters.com 41 Line Voltage MonitorThe control monitors the line voltage provided to the system. If the line voltage is too low, the s

Strany 37

42 www.statewaterheaters.com CONSTANT OUTPUT TEMPERATURE CONTROLWhile the temperature regulation in the previous section describes the features of te

Strany 38 - 38 www.statewaterheaters.com

www.statewaterheaters.com 43 HOUSEKEEPINGVacuum around base of water heater for dust, dirt, and lint on a regular basis. VENTING SYSTEM INSPECTIONAt

Strany 39

44 www.statewaterheaters.com softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions. The u

Strany 40 - 40 www.statewaterheaters.com

www.statewaterheaters.com 45 SNOW ACCUMULATIONKeep the area around fl ue terminal free of snow and ice. The appliance will not function properly if

Strany 41

46 www.statewaterheaters.com • Disconnect the hoses joining the tank and the heat engine (upper hose is water outlet and lower hose is water inlet).•

Strany 42 - 42 www.statewaterheaters.com

www.statewaterheaters.com 47 DIAGNOSTIC DISPLAYBy simultaneously pressing the “Mode” and “down arrow” buttons for 3 seconds the unit will allow acc

Strany 43 - MAINTENANCE

48 www.statewaterheaters.com If an error code is displayed, or odd behavior of the unit occurs, the fi rst corrective action should be to “Cycle the Po

Strany 44

www.statewaterheaters.com 49Fault Code DisplayedDescription CauseLockout typeRemedyE15Blower speed abnormal.Blower speed is 200RPM below the target

Strany 45

www.statewaterheaters.com 5GENERAL SAFETYBreathing carbon monoxide can cause brain damage or death.Always read and understand instruction manual.• I

Strany 46 - Cold Water

50 www.statewaterheaters.com Fault Code DisplayedDescription CauseLockout typeRemedyE33 Water Flow Valve Closed.The water valve did not open when atte

Strany 47

www.statewaterheaters.com 51These guidelines should be utilized by a qualifi ed service agent.Problem Possible Cause(s) What to doNOT ENOUGH HOT WATE

Strany 48 - 48 www.statewaterheaters.com

52 www.statewaterheaters.com Problem Possible Cause(s) What to doWHEN THE TAP IS OPENED, THERE IS NO HOT WATER OR THE HOT WATER TURNS COLD AND STAYS C

Strany 49

www.statewaterheaters.com 53 SERVICEIf a condition persists or you are uncertain about the operation of the water heater contact a qualifi ed service

Strany 50 - 50 www.statewaterheaters.com

54 www.statewaterheaters.com PARTS IDENTIFICATIONITEM # DESCRIPTIONA Baffl e, FlueB Hot Water Outlet Nipple (w/ Anode, Heat Trap)C T&P Relief Val

Strany 51 - TROUBLESHOOTING

www.statewaterheaters.com 55RONMLKJIHGFEDCBATQSP12U107654321ZYXWV119813

Strany 52 - 52 www.statewaterheaters.com

56 www.statewaterheaters.com REPLACEMENT PARTSDESCRIPTION KIT #Drain valve 9000058015T&P relief valve 9003741005Anode/MG/NIP/HT 9004333005Anode/

Strany 53

www.statewaterheaters.com 57LIMITED RESIDENTIAL GAS WARRANTYTHIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY If the glass lined tank in this w

Strany 54 - 54 www.statewaterheaters.com

58 www.statewaterheaters.com NOTES

Strany 55

www.statewaterheaters.com 59NOTES

Strany 56 - 56 www.statewaterheaters.com

6 www.statewaterheaters.com Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free se

Strany 57 - DISCLAIMERS

500 Tennessee Waltz Parkway, Ashland City, TN 37015Phone: 800-821-2017 • Fax: 800-644-9306Website: www.statewaterheaters.com

Strany 58 - 58 www.statewaterheaters.com

www.statewaterheaters.com 7

Strany 59

8 www.statewaterheaters.com FIGURE 1 GET TO KNOW YOUR WATER HEATER - GAS MODELS REPLACEMENT PARTS AND DELIMING PRODUCTSReplacement parts and recomm

Strany 60

www.statewaterheaters.com 9Capacity, Gas and Electrical CharacteristicsModel Approx. Capacity Input GasTypeGas Supply Pressure Manifold Pressure Ele